Paperless Chart Recorders Specification

  • Power
  • VAC: 100-240VAC, frequency: 47-63 HZ, max. power consumption: 5VA VDC: 24VDC,max power consumption: 5VA (please advise when order) Watt (w)
  • Temperature
  • 0-50C Celsius (oC)
  • Voltage
  • 05V, 15V, standard range: -20000 to 20000 Watt (w)
  • Warranty
  • 1 year
 

Paperless Chart Recorders Trade Information

  • Minimum Order Quantity
  • 1 Box
  • FOB Port
  • Courier
  • Supply Ability
  • 10 Boxes Per Week
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Contact us for information regarding our sample policy
  • Packaging Details
  • 100 % Safety Guarantee
  • Main Domestic Market
  • All India
  • Certifications
  • CE
 

About Paperless Chart Recorders

Paperless Chart Recorders (144x144mm, approximately 16 channels) is a color TFT LCD display; entirely secluded universal input like thermal resistance, thermocouple, current and voltage, regularity input, can sustain multi-loop flow totalizer with programmed temperature and pressure recompense function; accepts modular structure production functions like alarm, auxiliary control supply for sensors production, retransmission, print and communique etc. Gauging data can be showed in numerous types, like graphic display as bar-graph, history trending memory, real-time trending, history circular chart memory, real time circular chart, and alarming state show. Also can be published in curve and data by mini printer using RS232 port; At the similar time, it also delivers features to examine the data of month, day, year, hour, minute, second straight. Recorder can be conformation with SCADA system, OPC server, and other specialized software with MODBUS-RTU communique protocol via RS485 port. The history data can be copied directly by USB flash drive, play and plug, easy and supple. PC reinforced data examination software can design the data in curve and output Excel arrangement for further analysis.Khoat Make Color Paperless Recorder Number of Channels - 1, 8 or 16 Accepts 5.6-inch TFT color LCD, high lightness, wide visual angle, and contrast. English Menu intended. Simple and clear screen, kind human-meter operation screen, rich information, friendly - operator, easy operation Accept SMT technology, extra concise designed. Worldwide input for multi frequencies, adopt photoelectric separation amongst channels for evading the meddling among channels. T.C and RTD input accepts nonlinear alteration with high correctness and stable performance. Huge volume storage: 8MB for extended time record. Technical Specification : Analog Input Specification Input Signal : Linear Voltage : 0-5V, 1-5V, standard range: -20000 to 20000.: Linear current : 0-10mA ,should be external connection with 500 resistor; 4-20mA and should be external connection 250 precise resistor. Standard range: -20000 to 20000.: Thermocouple Input: K ( -50 ~ 1300oC ),S ( -50 ~ 1700oC ),T ( -200 ~ 350oC ), E ( 0 800oC ), J ( 0 ~ 1000oC ), B ( 300 ~ 1800oC ), N ( 0 ~ 1300oC ), R(-50-1700oC) , WRE526 (-0 ~ 2300oC), WRE235 (0 ~ 2300oC): RTD Input : Cu50 ( -50 ~ 150oC ) , Pt100 ( -200 ~ 600oC ), Cu100 ( -50 ~ 150oC ): Other linear input: 0-20mV,0-60mV, 0-100mV, 0-500mV, standard range : -20000 to 20000. Accuracy : 0.2 grade when RTD, linear voltage, linear current and T.C input: 0.2%FS+2.0oC when T.C input with cold junction compensation by internal part of recorder. Sampling Rate : 3 s Temperature Shift Coefficient : Standard value: 50PPM CMR Ratio : 85-110dB Input Independence : 500K when standard voltage input; 250 ( 4-20mA). Or 500 (0-10mA) when standard current input More than 20M when other signal input Isolation : Isolated voltage between channels and ground: 1000VAC.Isolated voltage between channels: 400VAC Thermocouple : Internal resistor: not more than 1000. Cold junction compensation tolerance: maximum +-2oC RTD : Current 2.5mA, three wire, each wire with same resistance: max.10ohm per each wire. Input Error Action : When T.C., RTD,1-5VDC, 4-20mA input and there is open or short circle, there are three ways available: measured value as maximum, minimum or hold Power Supply Specification Power supply : VAC: 100-240VAC, frequency: 47-63 HZ, max. power consumption: 5VA: VDC: 24VDC,max power consumption: 5VA (please advise when order) Insulation : When power insulation to ground is higher than 1500VAC, leakage current: 10mA for one minuteWhen power insulation to covering is higher than 1500VAC, leakage current: 10mA for one minute Output Specification Aux. power supply : 24VDC, 50mA Alarm Output : Up to 16 alarm output, 250VAC, 3A relay contact output: NO or NC Retransmission : Up to 6 channels, 4-20mA retransmission output with GND Others Processor : 32 bits, high performance, high integrated ARM CPU Hardware guider : CPU inner integration for long time, stable and safe operation Hardware Clock : Accept hardware real clock with high constancy. Clock accuracy: +-5ppm. After power off, Li battery for repeated power supply. The cogency of battery is 30days. Data Memory : All data will be stowed in FLASH memory, not essential reserve battery in order to safeguard that all the history data and conformation parameters will be not lost when power off.

FAQs of Paperless Chart Recorders:


Q: What types of input connections are supported by Paperless Chart Recorders?

A: Paperless Chart Recorders support all types of input connections, including RTD, linear voltage, linear current, and T.C inputs.

Q: What is the accuracy rating for Paperless Chart Recorders?

A: The accuracy is: - 0.2 grade for RTD, linear voltage, linear current, and T.C inputs. - 0.2%FS 2.0C when using T.C input with cold junction compensation by the recorders internal part.

Q: What are the power specifications for Paperless Chart Recorders?

A: Power specifications are as follows: - VAC: 100-240VAC, frequency: 47-63 Hz, maximum power consumption: 5VA. - VDC: 24VDC, maximum power consumption: 5VA (please advise when ordering).

Q: What is the physical size and installation size of Paperless Chart Recorders?

A: The physical size is 96mm x 96mm x 70mm, and the installation size is 92mm x 92mm.

Q: What is the operating temperature range for Paperless Chart Recorders?

A: The operating temperature range is 0-50C.

Q: What is the warranty period for Paperless Chart Recorders?

A: The warranty period is 1 year.

Q: What voltage range is supported by Paperless Chart Recorders?

A: The recorders support standard voltage ranges of 05V and 15V, with a measurement range of -20,000 to 20,000.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Paperless Recorders Category

Economic Blue Paperless Recorder

Economic Blue Paperless Recorder

Price 15500 INR / Box

Minimum Order Quantity : 1 Box

Warranty : 1 year

Accuracy : highaccuracy %

Function : Process Recording

Size : 160X80MM (LX W)

Color Paperless Recorder

Color Paperless Recorder

Price 16000 INR / Box

Minimum Order Quantity : 1 Box

Warranty : 1 year

Accuracy : (0.2%FS+1)digit %

Function : Process Recording

Size : 160x80x105mm

Mini Blue Paperless Recorder

Mini Blue Paperless Recorder

Price 10000.00 INR / Box

Minimum Order Quantity : 1 Box

Warranty : 1 year

Accuracy : +(0.2%FS+1 digit %

Function : Process Recording

Size : 72x72x105mm

Paperless Recorder

Paperless Recorder

Price 28000.00 INR / Box

Minimum Order Quantity : 1 Box

Warranty : 1 year



trade india member
MICON AUTOMATION SYSTEMS PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Private Limited.