Call Us
Head Mounted Smart Temperature Transmitter

Head Mounted Smart Temperature Transmitter

1400 INR/Box

Product Details:

  • Specimen Size Mount area: top of B type box Inch (in)
  • Temperature Storage temperature: -40 to 100℃ Celsius (oC)
  • Power Supply U=12V to 40V
  • Port Size Storage temperature: -40 to 100℃
  • Machine Weight Input: RTD, Thermocouple Metric Ton
  • Test Speed 8 kinds of thermocouple (TC)
  • Test Width 2 kinds of resistance thermometer input (RTD) Millimeter (mm)
  • Supply Ability : 100 Box Per Week
  • Click to view more
X

Price And Quantity

  • 1400 INR/Box
  • 1400.00 - 1400.00 INR/Box
  • 1 Box

Product Specifications

  • Configuration by PC
  • Mount area: top of B type box Inch (in)
  • Protection: IP00; IP66 (mounted)
  • Storage temperature: -40 to 100℃
  • 2 kinds of resistance thermometer input (RTD) Millimeter (mm)
  • Storage temperature: -40 to 100℃ Celsius (oC)
  • U=12V to 40V
  • Input: RTD, Thermocouple Metric Ton
  • 8 kinds of thermocouple (TC)

Trade Information

  • Courier
  • Western Union, Telegraphic Transfer (T/T), Letter of Credit (L/C), Cheque, Cash Advance (CA)
  • 100 Box Per Week
  • 7 Days
  • Yes
  • Contact us for information regarding our sample policy
  • 100 % Safety Guarantee
  • All India
  • CE

Product Description

Head Mounted Smart Temperature Transmitter

Head mounted temperature transmitter is used for resistance thermometer (RTD), thermocouple (TC), Resistance transmitter, voltage (mV) signal input, two wire 4-20mA analog output, mounted inside transmitter (form B)

Function

  • Transfer various kinds of input signal into 4-20mA output
  • Input: RTD, Thermocouple
  • Configuration by PC
  • 2 kinds of resistance thermometer input (RTD)
  • 8 kinds of thermocouple (TC)
  • Built-in cold junction compensation

Technical Specification

  • Output Signal: 4-20mA
  • Max Load:max. (V power supply-7.5V)/0.022A (current output)
  • Measurement:tempt-lineatiry,resistance-linearity, voltage-linearity
  • Circuit limit: 22Ma
  • Response time: 1second
  • Saturation current: Low side 3.9mA, high side 20.5Ma
  • Alarm current: sensor danger or sensor turn off output is 3.9mA or 22mA(except TC)
  • Accuracy: 0.1%FS
  • Measuring accuracy is related to measuring rang
  • Power supply: U=12V to 40V
  • Working temperature: -40 to 85
  • Storage temperature: -40 to 100
  • Condenstaion: Allowable
  • Protection: IP00; IP66 (mounted)
  • Earthquake resistance:4g/2 to 150HZ
  • Voltage effection: can ignore
  • Mounted angle: no limit
  • Mount area: top of B type box

MICON AUTOMATION SYSTEMS PVT. LTD.

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



MICON AUTOMATION SYSTEMS PVT. LTD. All Rights Reserved.(Terms of Use)
Developed and Managed by Infocom Network Ltd.